LiFePO4 Portable Power Station
Best for apartments & 12–36 hr outages
- Safe for indoor use, silent, and zero fumes.
- Capacity exceeds 3,000 Wh; this option can be expensive without solar.
- Recharge it according to the manufacturer's instructions.
OUTAGE BACKUP PLANNER
Choose your appliances and outage conditions for an instant, side-by-side backup power estimate.
Estimates are for planning. Check each appliance's nameplate and your equipment manufacturer's guidance.
THREE WAYS TO KEEP FOOD COLD
Compare estimated sizing, energy, and trade-offs for your selected load.
Best for apartments & 12–36 hr outages
Propane / gas · Best overall for 48–96+ hr outages
More output for the lowest upfront cost per watt
FREE CUSTOM LOAD SHEET
Get a clear summary of your current appliance and outage selections.
PRACTICAL SIZING GUIDE
A reliable refrigerator backup plan needs more than a wattage guess. Start with the appliance's actual electrical ratings, account for compressor cycling, and choose equipment that is safe for the place you intend to use it.
A refrigerator compressor draws a short burst of current as it starts. The Locked Rotor Amps (LRA) printed on an appliance nameplate can help indicate this starting demand; multiply amps by voltage for a rough watt equivalent, but note that motor power factor and equipment behavior make this an estimate. Running watts alone can understate the inverter or generator capacity needed. Check the manual and nameplate, and confirm the backup device can deliver both the continuous load and the starting surge. If several compressors might start together, allow for overlapping starts or manage them so they do not all start at once.
The compressor cycles on and off to maintain temperature, so its average energy use is usually lower than its running watts multiplied by every hour. The portion of time it runs is its duty cycle. Room temperature, door openings, food temperature, ventilation around the appliance, worn seals, and freezer defrost cycles all affect that fraction. The calculator estimates energy using a typical duty cycle and an adjustable usage factor; it cannot predict the exact runtime of a particular model. For better planning, use the appliance label or a plug-in energy monitor over representative days. Keep doors closed during an outage and avoid loading warm food.
Inverters and generators differ in the shape and quality of their AC output. A pure sine wave is close to utility power and is generally a suitable choice for sensitive electronic controls and motor-driven appliances. Some conventional open-frame generators produce higher Total Harmonic Distortion (THD), which may cause excess heat, noise, poor operation, or compatibility problems in certain equipment. Check the refrigerator manufacturer’s requirements and the generator’s published THD rating rather than relying on a “clean power” label alone. Never exceed a power station’s continuous, surge, or outlet ratings, and follow all instructions for grounding and connection.
Gasoline and propane generators produce odorless, potentially deadly carbon monoxide. Operate them outdoors only, at least 20 feet from windows, doors, and vents, with exhaust directed away from the building; never use one indoors, in a garage, or in any partly enclosed area. Install battery-powered or battery-backup CO alarms as directed by their manufacturers. Use a grounded, outdoor-rated extension cord sized for the load and length; a 12-gauge cord is often appropriate for a substantial appliance load, but confirm its amp rating and follow the generator and appliance instructions. Inspect cords, keep connections dry and elevated, and do not route them through doors where they can be pinched. Have a licensed electrician install any transfer equipment; never backfeed a home through a wall outlet.
All sizing and fuel figures are planning estimates, not guarantees. Verify nameplate ratings and consult a licensed electrician when selecting or connecting equipment.
COMING SOON
Purpose-built calculators for the equipment you rely on most.
Plan the starting surge and generator capacity for your well.
Estimate overnight runtime for sleep therapy equipment.
Understand backup needs for heat during an outage.
Compare cooling loads, startup needs, and battery runtime.